Diesel generator set a reliable backup power system is an integral part of data center design
In the digital age, data centers have become the core infrastructure supporting cloud computing, big data, and artificial intelligence.
Whether it's financial systems, e-commerce platforms, or government and corporate information systems, a power outage can lead to service interruptions, data loss, and significant economic losses.
Therefore, a reliable backup power system is an integral part of data center design.
Among numerous solutions, diesel generator sets remain the most stable, economical, and proven option.
--
I. Data Centers' Extremely High Requirements for Power Reliability
Data center power systems are typically divided into:
Utility Power
UPS (Uninterruptible Power Supply)
Diesel Genset Backup
When the utility power is interrupted, the UPS provides short-term power within seconds, while the generator set automatically starts and takes over the load within tens of seconds, ensuring continuous power supply for extended periods.
The industry generally requires data centers to achieve Tier III or Tier IV (Uptime Institute) power reliability, corresponding to 99.982%–99.995% availability.
II. Core Advantages of Diesel Generator Sets
1. Fast Response
Automatic start-up time is typically within 10–30 seconds, ensuring load takeover before the UPS discharges.
2. Stable Output Power
Strong load response capability, capable of withstanding sudden power fluctuations in data center equipment.
3. Easy Fuel Access and Long Reserve Life
Diesel is easier to store, transport, and maintain than natural gas or battery energy storage.
4. Reliable Operation and Proven Technology
Equipped with a comprehensive control system and monitoring interface, it can be integrated with the data center's BMS/EMS system.
5. Strong Scalability
Supports parallel operation of multiple units, facilitating phased expansion and redundant configuration of data centers.
III. Typical Configuration
A typical data center backup power system typically includes:
High-power diesel generator sets** (such as 1000kVA, 1500kVA, 2000kVA, etc.)
Automatic synchronization system**
Double-walled fuel tank**
Silencer system and exhaust and smoke exhaust design
Remote monitoring and automatic switching control (ATS + AMF)
For example, a 2 x 2000kVA parallel system can meet the backup power needs of a medium-sized data center (1000 racks).
IV. Green Energy Saving and Future Trends
While diesel generator sets remain the primary backup power source for data centers, the industry is actively moving toward **low emissions and intelligent** technologies:
Adopting Euro III/Euro V emission standard engines
Introducing AdBlue/DEF systems to reduce NOx emissions
Using biodiesel (Biodiesel/HVO) instead of traditional fuel
Remote monitoring and predictive maintenance (IoT + AI)
Combining hybrid backup systems with battery energy storage systems (BESS)
Some large cloud service providers (such as AWS, Google, and Microsoft) have already tested "diesel + energy storage" hybrid energy systems in their next-generation data centers.
Conclusion
With the rapid development of the digital economy, the scale and importance of data centers continue to rise.
Among all support systems, diesel generator sets remain the critical "last line of defense"—ensuring that servers will not stop operating due to power outages under any circumstances.
Through high-quality unit configuration, scientific maintenance and management, and the introduction of green energy technologies, diesel generators will continue to play a stable and important role in future data center energy systems.